Aux heat kicking on now and then
Cold snap hits, your heat pump calls for aux, and it clears once the house warms back up. The outdoor unit runs quiet, the coil stays clean, and the thermostat drops out of AUX on its own within an hour or so.
Tell a local repair pro what your heat pump is doing.
Get matchedYour thermostat shows "AUX" or "AUXILIARY HEAT" and the system seems to be working harder than usual. You want to know if that's normal or a sign something's wrong, especially since your home heats with gas and the heat pump might only be handling part of the job.
A heat pump moves heat from outside air into your home, but when it's cold enough outside, it can't pull in heat fast enough to hit the temperature on your thermostat. Auxiliary heat is the backup that fills that gap, usually electric resistance heat built into the air handler, or in a dual fuel setup, a gas furnace that takes over. In Nevada, most homes heat with gas, so if yours has a heat pump at all, it's likely paired with a furnace as backup rather than running on electric strips. Seeing AUX light up on a cold morning is normal. If it's staying lit through mild weather, the heat pump itself isn't keeping up, and that's worth a look.

Cold snap hits, your heat pump calls for aux, and it clears once the house warms back up. The outdoor unit runs quiet, the coil stays clean, and the thermostat drops out of AUX on its own within an hour or so.

If AUX stays lit for hours or runs nearly every cycle, the heat pump isn't keeping up on its own. Check the outdoor unit for ice built up on the coil or lines, or for a fan that isn't spinning. A unit that looks like this needs a look from someone who works on them.




Your heat pump's outdoor unit is built to pull heat out of the air outside and move it into your house. That works fine most of the year here, but Nevada nights can still drop cold enough that there isn't enough heat left in the outdoor air to draw from. The system doesn't stop. It switches on a backup heater built right into the air handler, a set of electric coils called a heat strip. That strip doesn't move heat from anywhere, it just gets hot itself, the same way a toaster element does, and the blower pushes air across it into your ducts. Your thermostat labels this AUX because it's a second, separate heat source from the outdoor unit, and it reports it any time that strip is drawing power, not just when something's gone wrong.
There's a second reason AUX shows up that has nothing to do with the cold. When the outdoor coil picks up frost, which happens during normal operation in cold, damp air, the system has to pause and run a defrost cycle to clear it. During that pause the outdoor unit isn't producing heat, so the heat strip carries the house for those few minutes. That's a normal, built-in part of how the system runs, and it's a different situation than the strip running because the outdoor unit can't keep up or has failed outright. Both show the same word on the thermostat, which is why AUX alone doesn't tell you which one you're looking at.


Most homes here back up the heat pump with gas, so when AUX lights up, it's the electric strips doing work your furnace would normally take care of. That's fine for a cold snap. Power here is cheap, so a strip running an hour or two while the house catches up won't show much on the bill. The problem is when AUX stops being occasional. If it's running most of the day, or it won't clear even after the house has warmed back up, something besides the weather is making the heat pump reach for it. A dirty outdoor coil or a refrigerant charge that's dropped will both push the system into AUX more than it needs, and that's a mechanical problem wearing on the heat strips every time it happens. A relay that's stuck, or a sensor reading wrong, can keep AUX on even when the house doesn't need it. None of these show up as a big event. They show up as AUX running longer than it used to, which is the kind of thing worth checking before it turns into a bigger repair.


The pro who reaches out is licensed in Nevada.
It costs nothing to send, and you don't have to hire anyone.
In your house, aux heat showing up for an hour during a cold snap is nothing to worry about. What matters is whether it stays lit. If the AUX light stays on for most of a day, or if it comes on even when it's not that cold outside, something is making your heat pump work harder than it should to pull heat from the air. That could be a dirty outdoor coil, a low refrigerant charge, or a reversing valve that isn't switching the way it should. Power here is cheap, but electric strip heat still costs more to run than your gas furnace, so a heat pump leaning on aux too often shows up on your bill before you ever see it on the thermostat. Left alone, the same problem that's pushing the system into aux now is often the one that leaves you with no heat at all on the next cold morning. Catching it while it's still just aux kicking on more than it should is the cheaper fix, and the easier one.
At 13.26 cents a kilowatt-hour, aux heat here isn't ruinous when it only runs an hour or two during a cold snap. But electric strips use far more power than your heat pump's compressor, so if aux is stuck on for hours at a time, that rate starts showing up on your bill fast.
EIA-861 2025 statewide residential average
A heat pump defrosts itself by briefly running in cooling mode to melt frost off the outdoor coil, and while it does that, it kicks on aux heat so the air coming out of your vents doesn't turn cold. A normal defrost cycle lasts a few minutes, maybe once an hour in freezing weather. If you walk outside and see the outdoor unit coated in ice rather than just frosted, or if the fan has stopped turning, the defrost cycle isn't finishing the way it should, and aux heat ends up carrying the load far longer than a few minutes at a time.
Electric heat strips are simple, just resistance wire like what's in a toaster, but they still wear out. A strip can crack or burn through after enough cycles, and when that happens the system either loses aux heat entirely or trips a limit switch that shuts the whole unit down. A failed strip won't always throw an error your thermostat shows plainly. Sometimes the only sign is that AUX comes on but the air at the vent never actually warms up, which is a different problem than aux running too long and worth telling a contractor about separately.



Nevada summers don't carry much moisture, and the numbers back that up. Averaged across homes here, the dew point sits at 37°F through June, July and August, according to NOAA climate data. That's dry air, and dry air gives your heat pump's outdoor coil an easier job shedding heat when it's cooling your house. It's a different story in winter, though. The same dry air outside means less moisture for the coil to pull heat from on a cold morning, which is part of why aux heat steps in more readily here than it would somewhere humid. If your heat pump leans on aux often on cold mornings, that's the dry air working against it, not a sign the unit is failing.
NASA POWER T2MDEW county cells weighted by homes

A light that clicks on during a cold snap and clicks off within an hour is your system doing what it was built to do. What's worth a call is aux that won't quit, a coil you can see is dirty, or a defrost cycle that runs long and often. Those are signs the heat pump is leaning on the electric strips more than it should, and with gas as your backup, that's not how the system is supposed to carry a cold day.
If that's what you're seeing, a local contractor who works on heat pumps all season can look at the coil, the defrost board, and the strips themselves and tell you which one is making aux run longer than it needs to. You'd be matched with one contractor who services your area, not a handful calling you back, and the person who reaches out will already know what tends to fail on these systems when aux won't shut off.


A pro who works on heat pumps